- Cross-section x mm²
-
2 x 0.75
- Temperature range
-
bewegt: –5° C bis +70° C, ruhend: bis –30° C
- External diameter
-
6.7 mm
- Conductor
-
Stranded wire made of bare copper fine wire, according to VDE 0295, class 5
- Isolation
-
Cores: PVC, according to VDE 0207, part 4, Sheath: PUR
- Strand identification
-
Cores blue and consecutively numbered
- Isolation resistance
-
> 1000 MOhm / km
- Sheath/ mantle
-
PUR
- Applications
-
Damp rooms (not for outdoor use) / Heating and air conditioning technology / Measurement and control lines in machine tool manufacturing
- Test voltage
-
3000 V
- Turning length
-
0.6 m
- Usable length
-
1.8 m
- Free ends
-
0.2 m
- Colour
-
Blue
- Voltage
-
Uo / U max. 500 V